SENKO MGT

Multi Gas Detector

MGT is a united gas detector measuring four(4) major gases, which cause most of the industrial accidents, to protect workers from the disasters caused by the Oxygen deficiency, Toxic gas poisoning and gas explosion. It measures continuously four(4) gases(O2, CO, H2S and Combustible Gas(CH4) and displays their concentrations and raises an alarm(visual, vibrating, and audible) when the risk occurs. It features the dual sensor of CO and H2S.
Features
• Small size & Light weight
• Rechargeable battery
• 30EA of Bump tests/ Events/ Cal.
• Simultaneously detect 4 different gases
• 25 hours use by one charge for 4-6 hours (P-type)
• 60 days use by one charge for 4-6 hours (N-type)
• Configuration via exclusive IR Link
• Easy check & calibration via Docking Station
• Intrinsic Safety
Specification
Specification Table
Item Specification
Gas detected Oxygen(O2)、Carbon Monoxide(CO)、Hydrogen Sulfide(H2S)、Combustible Gas(CH4)
Measuring Ranges O2:0~30% vol、CO:0~500 ppm、H2S:0~100 ppm、CH4:0~100% LEL
Sensors O2, CO and H2S : Electrochemical, Combustible(LEL): IR or pellistor
Detection Diffusion/ sampling(optional sampling pump)
Self test Full function self-test upon activation Sensors, battery and circuitry - continuous
Display LCD Display (Back-light)
Alarms User selectable low and high alarms.
Ultra bright LEDs. Buzzer (more than 90dB) alarm. Vibrating alarm.
Alarm change Via Instrument & MGT-IR Link, available
Battery Rechargeable Li-ion power supply unit (2000mAh)
Battery life IR: 60 days continuous / Pellistor: 25 hours continuous
Charge time 4-6 hours
Data logging DATA logging with MGT-IR Link Connection. Bump test station(optional)
Dimensions 61mm × 114mm × 43mm
Weight 240g
Temperature -20°C to 50°C
Humidity 10% to 95%RH
Approval IECEx Ex ia IIC T4 IP:67(on going)
Buttons Two( “Arrow” and “OK”)